BioConnect®
Optimized recess contour (patent approved)
Highest press-on power at the transitions to wetted areas prevents dirt and germs getting into the sealing space (see ASME-BPE, Ch. SD-3.7.2 and 3.7.6)
Defined expansion pockets excludes dangerous "escalator effect" between wetted area and elastomer seat (see ASME-BPE, Ch. SD-3.7.2)
Self-draining even after expansion of seal due to high temperature (see ASME-BPE, Ch. SD-3.7.7)
Metal-to-metal-stop avoids stress or overcompression of gaskets (O-ring) (see ASME BPE, Ch. SD-3.7.8)
Nominal pressure PN16 (D6 - DN100, ½“ - 4”)

Connect S® - a unique solution without elastomer gasket
Optimal recess contour and design of the sealing metallic surface (patent approved)
Excellent cleanability
Tested by Fraunhofer-Institut for Grenzflä chen-und Bioverfahrenstechnik 
Hermetic tightness even under repeated temperature changes
Defined pre-stressing on the metallic sealing surface
No gasket - no elevator effect
Protection of the sealing contour against damage
Axial positioning by metal-to-metal-stop
Exact positioning by central guidance
Material grade 1.4435/316 L; other grades on request
Wetted areas with roughness Ra<0,8µm (Ra<0,5µm on demand)
Dimensions acc. ASME-BPE, DIN11866, DIN 11850,ISO 1127
Material Test Report according EN 10204-3.1 (on requestADW2)
Approval for pressure application: issued by TUV Germany (SU ddeutschland) a) Nominal Pressure: PN 16 (DN 6 until DN 50)
PN 10 (DN 65 until DN 100)
PN 100 (DN 6 until DN 40, high pressure-aseptic connection)
BioControl®
BioControl® is a fully aseptic modular system with T?V-approval for pressure application. BioControl® provides the user with a fully hygienic port for connecting control instruments, gauges, sight glasses etc., allowing cleaning and sterilizing in place.
BioControl® system is supported by the following manufacturers of instruments and special equipment:
Endress + Hauser
WIKA
LABOM
Fisher Rosemount (EMERSON)
Papenmeier
Others BioControl® allows 100% Cleaning-In-Place where typical instrument tees stay with uncleaned dead pockets.
|
Example: Inline – Housing |
Example: Angle – Housing
|
|

|

|

|